MiTS 2
New Feature
- User now can sync MiTS 2 Project File to Civil 3D
- User can now insert title block for cross-section/cut-section layout
- User can customize the layout scale for cut-section with title block
- Some MiTS 3.0 feature can be access if user using the Cloud License
- User can named the Running System for Water Rec/Drain/Sewer
Earthwork
- Allow merging of Earthwork and Road Platform
- Add Tracing Drawing in 3D IFC Export file
- User can choose a different meshing method for each survey point group when computing two separate survey point groups.
Road
- User can choose which guidelines they want to use for Curve Widening Table either AASHTO or ATJ
- User can choose which details that need to be included in the Road Cross-Section
- User can choose multiple option of Horizontal Curve Calculation
- User can edit the spiral length value
- User enters a runout length value that less or more than the ATJ, a warning will appear at verification tab
Drain
- The IL of the node is been displayed in the Input Screen
Water
- Output for Water Reticulation as per Syarikat Air Johor (SAJ) standard
- User can choose whether to segregate or not the results as per their submission requirement
- In the Textual Report, the inner and the outer pipe diameter is shown
MSMA
- Implementation of Sharp Crested Weir method for Secondary Outlet of Detention Pond
- ESCP Design
- Sediment Yield is included in Site Condition
- C & P factor is include in the Calculation and Detailing
- User can define site condition remark
- Runoff Coefficient is include so user can just refer directly during the design process
- User can design Underground OSD with pipe or box culvert
Clash Analysis
- Clash analysis will check the crossing utilities even the utilities is at the different level
- Long Section also showing same utilities crossing each other at different levels
Enhancements
- When reopened, the filter on the verification tab will use the most recent settings
- User can eliminate ‘Degenerated points’ during survey point import process
- Zoom in and pan around more smoothly because software takes shorter time to process and respond to cursor movement.
- Snap function more snapper
- User can choose to backup file with or without loupe file to reduce the size of the zip backup file
- Software will produce a detailed warning if the file name is too long
Earthwork
- Software will give user tool tip when user try to do Cut and Fill analyze without importing the survey point
- Changing the gap length between tadpole slope
- User can choose either to include all survey point or not
- Software provide a verification warning when TRN is not generating enough triangle elements
- Time required is reduced to check overlapping platform
Road
- Input screen would not zoom out when selected an element
- Allow user to choose which superelevation table user want to use in the design
- Software will give user a warning if end chainage is negative number
Drain
- Drainage analysis more consistent
- Software will produce a warning when drainage diameter is smaller than freeboard
- User may choose the average velocity equation for open drains
- User no need to insert the H1 value for the Block, RC as it will be computed by software
Water
- User can edit column sequence and description for summary table
- In Schematic Plan can show the name of ‘Running Network’ for pipes
- Output result is in 3 decimal point as per RSAJ Requirement
Sewer
- There will be a warning if the pipe length is not entered correctly. However, it will have no effect on the analysis process
MSMA
- Tcpost > Tcpre warning will appear at both Time-Area method and Rational Method
- User can redownload Google Terrain Map when the Rainfall Gauge Map is not displayed with a Google Terrain Map
- By default there is no checking of Q primary outlet against PSD at OSD design
Bugs Fixes
- No crashes when to change the Water Level layers color
- When click at the toggle entity, only utilities layers ‘ON’
- 3D screen will not switch to any other screen when user try to click node/pipe
- Now when user save the project with name contain “/” character or any invalid character there is a warning will popup
- The layers properties changes will reflected directly at the Cross-Section/Cut-Section/Long-Section and also Input Screen
- Double line to indicate the outer and inner layer of the pipe is fix
- Pan zoom in/out respond immediately
- The counts for Errors and Warnings at Verification tab will show the verification for the active module only
- IL of the utilities is been preserve when merging project file
- Contour line can be display at 3D View without bug
- Input nodes of the pipe/drain can be done without bug
- Project parameters Data is preserved when Save and Load the parameters
Earthwork
- User can proceed design dry sediment basin when Tc > 60 min
- User can import google earth points smoothly
- After breaking the platform, the platform height data will immediately update with the inputted height.
- Slope produced start/end at the platform/OGL
- When a user clicks the Next/Previous Platform button in Platform Editor, the input screen is directly reflected to show which platform it is.
- Cross-Section shows All will now showing all cross-section include MasterStrings and End Area without missing any cross-section
- The Earthwork Report’s bounded area has improved its accuracy.
- User now can input a platform that has more than 10 points smoothly
- DTM cut and fill contour is properly filled
- User can create new platform without crashing
- Platform height at the input and key plan drawing is synchronized
- Topsoil depth properties is instantly updated
- Layers drawing properties is instantly updated
- Platform height and marking are updated instantly
- User can edit platform height directly at the Platform Height Text without an issue
Road
- User can manually input design speed without any restriction/limitation
- Chainage interval changed at the parameter will reflect directly at the cross-section and road end area report
- Once user make a change at the road design standard the software will update it directly
- CAD measurement can be use at the output Horizontal Detailing
- Real-time verification has been updated
- Time taken for road analysis has been reduced for bigger project
- The spread input table will update accordingly when user change the Runout Calculation method from Auto Calculate to User Defined
- Transition Length formula is include in appendix
- User may generate slopes at Road Module smoothly
- No crashers occur while designing the road
- User may generate drain in the road module without crashes
- Survey point data is more stable, hence generated end area report is more consistent
Drain
- Long Section can be produced like usual
- Time required to import Drainage key plan had been reduced
- Td and the Tc value of the drainage can be produce as usual
- The amount of time required to analyse the drain is reduced
- Textual Report produced will be based on the which MSMA guidelines user use
- User can delete the drain size at the Project Parameters
- Road superelevation will be reflected at the road cross-section
- The user can add/remove drain vertex without crashing
- User can change the starting Chainage of the road without crashing
- The iteration IL more closely reflects the input’s fixed gradient
- The Spread Input Value precisely matches with Long Section details
- User can adjust IL or gradient of the drain without close the Long-Section tab
- Ground level at the Drain Long-Section is more consistent after multiple analysis
Water
- Water Reticulation can be analyze even without hydrant
- Average Flow Analysis excel file can be export as usual
- When changed the table description at Project Parameters, the description at the table output is the only things that follow the changes. Other would not example, the keyplan output.
- User may make changes Running Pipe system at Project Parameters without crash when user make any other changes
- Nodes marking will no longer affect the analysis process
- User can sync MES Modules Project File Directly to MiTS 2 smoothly
Sewer
- QS report can be included during the Batch Report
- The Colebrook-White Equation is included in the Textual Report
- MiTS 2 can open the SewNet (MES Module) project file
- User can input Main Forces properties
- Deleting sewer pipes and nodes respond immediately
MSMA
- User may Batch Export for graphs output without error
- Pond details will instantly update when user change the pond type at pond sizing and click the ‘Synchronize with MiTS-Earthworks’
- EW Pond Platform can be synced as usual even if another pond platform is close the assigned pond platform
- Pond platform can be synchronization in Pond – Time Area Method
- IDF Value will follow drain synchronized value for Pond design
MCIntegrator
- User can synchronized MiTS 2 Project file into Civil 3D
- Allow full synchronization of 3D View
- Specific warning will be produced if MiTS 2 project file is cannot open in Civil 3D
- Fix on the disconnected of pipe and fittings when editing the MiTS 2 Project file in Civil 3D
- Warning will be given is 3D View path is missing instead of program crashing
- User can edit pressure networks and pipe networks for the infrastructure entities in Civil 3D without crashes
- Software will produce warning when user not update the 3D View file in Civil 3D after make changes in MiTS 2
- User can sync utilities object as CIVIL Object fully without a bug
- Fix on different value IL in MiTS and Civil 3D
- Fix on ground Level for Nodes becomes Zero
- Is compatible to use in Civil 3D 2023 version
- Allow user to select which survey points they want to import from MiTS 2 to Civil 3D
- Warning will be produce if user do not defined the Civil 3D Surface instead of crashing
- Synchronization of multiple network for MCIntegrator
- Synchronization of Platform Surface for MCIntegrator
- Synchronization of Platform Surface from Civil 3D to MiTS
- Warning will be given when platform mark is null instead of crashing
- Parameters settings as a NoSync can be done successfully
- Verification error showing no corresponding MES pipe type in parameter
- Tooltip will be given if user make any changes in the parameters. As it will affect the newly added structure only