title: Pressure Network Automation
description: "# **Profile View** The Profile View will be automatically generated for pressure networks (water reticulation) synchronized from MiTS to Civil 3D. The generated diagram should correspond with the Long Sections in MiTS. ![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image9-2.png?resize=1024%2C387&ssl=1) ## **Steps:** 1. Each profile view has…"
url: "https://mes100.com/docs/pressure-network-automation/"
updated: "2026-08-19"
category: "MCIntegrator-Genabler / Output"
tags:
  - BIM
---

# Pressure Network Automation

# **Profile View**

The Profile View will be automatically generated for pressure networks (water reticulation) synchronized from MiTS to Civil 3D. The generated diagram should correspond with the Long Sections in MiTS.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image9-2.png?resize=1024%2C387&ssl=1)

## **Steps:**

1. Each profile view has been set to the dedicated Genabler Stylings. To check or update the stylings, users may navigate to the **Profile View Properties**.

Select any of the Profile Views for the network > Right-click > Click on Profile View Properties

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image10-2.png?resize=1024%2C452&ssl=1)

1. The Profile View is also set to follow the dedicated **Genabler Bandsets Selection**. To check or update the bandsets selection,

Under the Pressure Networks Automation section, click on the ‘Profile View’ dropdown > Click on ‘Change Profile View Bandsets’

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image30-1.png?resize=1024%2C203&ssl=1)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image5-3.png?resize=1024%2C532&ssl=1)

1. To **clear the Profile View**,

Under the Pressure Networks Automation section, click on the ‘Profile View’ dropdown > Click on the ‘Clear Profile View’ button

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image33-1.png?resize=1024%2C203&ssl=1)

# **Table**

This is a feature that allows users to add a Pressure Pipes and Fittings Table following the dedicated Genabler Styling.

## **Steps:**

1. Go to the MES Tab. Navigate to the Pressure Networks Automation section on the top ribbon.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image23-1.png?resize=1024%2C115&ssl=1)

1. Click on the dropdown of the ‘Table’ button. Click on ‘Add Table’.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image8-2.png?resize=1024%2C179&ssl=1)

1. The software will launch the **Pressure Pipe Table Creation**. Set the **Table Style** (by default, it is set to the dedicated Genabler Styling), **Network**, and **Table Configurations** (rows, columns, table behavior, etc.).

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image36-1.png?resize=1024%2C423&ssl=1)

1. Click OK. Select the upper left corner to place the table on the drawing. Once the table has been set, the software will open the **Fitting Table Creation**, which requires users to set the stylings and table behaviors.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image27-1.png?resize=1024%2C536&ssl=1)

1. Click OK to place the **Fitting Table**. Once the table has been set, the software will open the **Appurtenance Table Creation**, which requires users to set the stylings and table behaviors. Click OK to place the **Appurtenance Table** on the drawing.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image51.png?resize=1024%2C623&ssl=1)

1. Do note to place the **Fitting and Appurtenance Tables at a gap** from the **Pressure Pipes Table** to prevent overlapping between the two tables.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image29-1.png?resize=1024%2C429&ssl=1)

# Networks Labeling

Each of the fittings and pressure pipes is labeled with the properties, following the dedicated Genabler Stylings. To add the label,

## **Steps:**

1. Go to the MES Tab. Navigate to the Pressure Networks Automation section on the top ribbon.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image23-1.png?resize=1024%2C115&ssl=1)

1. Click on the dropdown of the ‘Label’ button. Click on ‘Add Plan Label’.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image15.png?resize=1024%2C231&ssl=1)

1. The network will be updated with labels that display the properties of the fittings and pressure pipes.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image47.png?resize=1005%2C782&ssl=1)

1. To **clear the Labels**,

Under the Pressure Networks Automation section, click on the ‘Label’ dropdown > Click on the ‘Clear Plan Label’ button

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image22-1.png?resize=1024%2C231&ssl=1)