title: How to add new structures or pipes/drains sizes in Genieko Library?
description: "With no similar diameters between the MiTS catalog and the Genieko Gravity Pipe Network library for the structures (nodes) or pipes/drains, the synchronization will fail with a verification error: “***Unable to Swap Part to the size….***”, as in the image…"
url: "https://mes100.com/docs/how-to-add-new-structures-or-pipes-drains-sizes-in-genieko-library/"
updated: "2026-08-19"
category: "MCIntegrator-Genabler / FAQ"
tags:
  - BIM
---

# How to add new structures or pipes/drains sizes in Genieko Library?

With no similar diameters between the MiTS catalog and the Genieko Gravity Pipe Network library for the structures (nodes) or pipes/drains, the synchronization will fail with a verification error: “***Unable to Swap Part to the size….***”, as in the image below.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image1-4.png?resize=1024%2C506&ssl=1)

With the Genabler plugin, users have the flexibility to *add specific sizes for the structures and pipes* easily— there is no need to go through the trouble of adding the diameters or modeling the required sizes through the **PartBuilder** **in Civil 3D**.

**Note:**The steps below are ONLY applicable to the **Genieko Gravity Pipe Network Library**.

# **Steps to resource up:**

1. Go to the Genabler tab in Civil 3D.

1. Navigate to the **Resource Up** section.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image8-3.png?resize=1024%2C99&ssl=1)

## **Add sizes for structures:**

1. Click on the ‘Add Sizes Structure’ button.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image13-2.png?resize=1024%2C99&ssl=1)

1. The software will open the **Add Gravity Part Sizes** dialog. Users will need to click on the ‘Circular’ or ‘Rectangle’ tab depending on the shape of the structures to be added.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image2-5.png?resize=962%2C462&ssl=1)

1. Input the **Inner Diameter, in mm**. Click on the ‘Add’ button.
   - For example, add a Rectangular Sump with sizes: **InnerW=1400, InnerH= 1400**

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image15-1.png?resize=955%2C459&ssl=1)

1. The software will display a message, “***Structure Size Added***”. Click OK to close the message and click ‘Close’.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image11-3.png?resize=957%2C451&ssl=1)

## **Add sizes for pipes:**

1. Click on the ‘Add Sizes Pipes’ button.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image16-2.png?resize=1024%2C99&ssl=1)

1. The software will open the **Add Gravity Part Sizes** dialog. Users will need to click on the ‘Circular’ or ‘Rectangle’ tab depending on the shape of the pipes to be added.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image5-4.png?resize=955%2C456&ssl=1)

1. Navigate to the category of the pipes. Input the **Inner Diameter and the Wall Thickness, in mm,** for the pipes.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image10-3.png?resize=946%2C454&ssl=1)

1. Click the ‘Add’ button. The software will display a message, “***Structure Size Added***”.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image4-5.png?resize=949%2C450&ssl=1)

1. Click OK to close the message. Click the ‘Close’ button.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image6-3.png?resize=949%2C450&ssl=1)

# **Where to check the added sizes?**

1. With the network synced ‘half successfully” (due to some unavailable sizes for the structures or pipes/drains), select any of the pipes or structures available in the drawing.

1. At the top ribbon, click on the ‘Part List’ button.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image3-5.png?resize=1024%2C123&ssl=1)

1. Click the ‘Edit Part List’ button.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image14-2.png?resize=1024%2C232&ssl=1)

1. Select **Genieko Part List**. Click on the ‘Edit’ button.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image12-2.png?resize=333%2C199&ssl=1)

1. Navigate to the Pipes or Structures tab under the **Network Parts List - Genieko** dialog. Expand the category for which new sizes have been added for the pipes or structures. The new size added should be listed accordingly.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image7-3.png?resize=988%2C784&ssl=1)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image9-3.png?resize=976%2C774&ssl=1)

### *Related*

 [![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/10/me-small.jpg?resize=100%2C100&ssl=1)](https://mes100.com/author/admin/)[Ngu Soon Hui](https://mes100.com/author/admin/)

I’m the [Benevolent Dictator for Life](https://en.wikipedia.org/wiki/Benevolent_dictator_for_life) for MiTS Software cum Editor of this website. Read more [here](/about-ngu-soon-hui/).

You can also contact me at soonhui@mes100.com