---
title: "Gravity Pipe Network (MCIntegrator-Genabler Synchronization): Guide for Sewerage & Drainage"
description: "# **Sewerage or Drainage Mapping Definition:** Please refer to the guide– ***[Required Mapping Definition for Gravity Pipe Network (Sewerage or Drainage)](https://mes100.com/docs/gravity-pipe-network-synchronization-guide-for-sewerage-drainage/#0-toc-title)***. ![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image4-3.png?w=1080&ssl=1) *Sewerage Settings Definition* ![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image37.png?w=1080&ssl=1) *Drainage Settings Definition* # **Sync Steps:** ## **In MiTS** 1. Go to the utility…"
url: "https://mes100.com/docs/gravity-pipe-network-mcintegrator-genabler-synchronization-guide-for-sewerage-drainage/"
updated: "2026-09-07"
category: "MCIntegrator-Genabler / Synchronization / Gravity and Pressure Networks"
tags:
  - BIM
---

# Gravity Pipe Network (MCIntegrator-Genabler Synchronization): Guide for Sewerage & Drainage

# **Sewerage or Drainage Mapping Definition:**

Please refer to the guide– ***[Required Mapping Definition for Gravity Pipe Network (Sewerage or Drainage)](https://mes100.com/docs/gravity-pipe-network-synchronization-guide-for-sewerage-drainage/#0-toc-title)***.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image4-3.png?w=1080&ssl=1)

*Sewerage Settings Definition*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image37.png?w=1080&ssl=1)

*Drainage Settings Definition*

# **Sync Steps:**

## **In MiTS**

1. Go to the utility module (sewerage/stormsync) and check the Nodes and Pipes information below:

   - Manhole/Sump Type
   - Manhole/Sump Diameter
   - Pipe/Drain Types & Diameters
   - Running Network
2. Ensure the **Manhole/Sump Type and Pipe/Drain Type are set to Genieko Category**, which follows the same diameter as the Genieko Part List for Gravity Network in Civil 3D.
3. Assigning the Genieko Category in MiTS allows us to apply **Default Mapping – Genabler** for the pipe and structures mapping definition during the Civil 3D sync. This automatically maps the MiTS category to Genieko Part Families, significantly reducing the percentage of synchronization errors.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image7-1.png?w=1080&ssl=1)

*Example of Sewer Node Manhole Profile*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image13.png?w=1080&ssl=1)

*Example of Sewer Pipe Type*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image12.png?w=1080&ssl=1)

*Example of StormSync (Drainage) Node Sump Profile*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image29.png?w=1080&ssl=1)

*Example of StormSync Drain Type*

## **In Civil 3D**

1. For gravity pipe network sync, it is **highly recommended that users also sync the [Surface](https://mes100.com/docs/surface-platform-synchronization-step-by-step-guide/#2-toc-title) and [Platform](https://mes100.com/docs/surface-platform-synchronization-step-by-step-guide/#7-toc-title)** to define the Reference Surface of the structures.
2. Under Project definition, click on the Sewerage Pipe Sync Tab/Drainage Pipe Sync Tab and define the **[required mapping above](https://mes100.com/docs/gravity-pipe-network-mcintegrator-genabler-synchronization-guide-for-sewerage-drainage/#0-toc-title)** as follows.

   - Set the sync mode to **Civil Sync** to ensure the entities are integrated as Civil Objects in the drawing file.
   - Set the Pipe and Node Dimension Synchronization according to the numerical diameter value in MiTS and the Genieko parts’ diameter. By default, the **pipe is set to the Inner Diameter based on ByDataField**, while the **node/structure is set to the Outer Diameter based on ByDataField**.
   - As an example,
     - Pipe Dimension Synchronization: **Inner Diameter; ByDataField**
     - Node Dimension Synchronization: **Inner Diameter; ByDataField**

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image31.png?w=1080&ssl=1)

*Example of Sewer Pipe Dimension Synchronization*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image14.png?w=1080&ssl=1)

*Example of Manhole Dimension Synchronization*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image35.png?w=1080&ssl=1)

*Example of Drainage Pipe Dimension Synchronization*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image33.png?w=1080&ssl=1)

*Example of Sump Dimension Synchronization*

1. Define Civil 3D Networks corresponding to the available MES Network- Click ‘Add C3D Network’ > Define the network name > Select the **Genieko Part List** as the Network Part List.
   - Note: The **Genieko Part List** will contain the pipe and structures for the gravity pipe networks.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image25.png?w=1080&ssl=1)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image10-1.png?w=1080&ssl=1)

1. Click the ‘Edit’ button for the defined network. For the Structure/Node and Pipe/Edge Mapping, it is now automated by clicking the ‘**Default Mapping – Genabler**‘ button.
   - Note: For **Default Mapping – Genabler**, the MES Category of the pipes and nodes **must be set to Genieko**. Then only the software can map the MES Category ‘Genieko’ to the corresponding pipes or structures from the Genieko Part List.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image28.png?w=1080&ssl=1)

*Manhole (Node) and Pipe Category set in MiTS*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image8-1.png?w=1080&ssl=1)

*Default Mapping – Genabler applied for sewer pipe sync*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image34.png?w=1080&ssl=1)

*Sump (Node) and Drain Category set in MiTS*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image9-1.png?w=1080&ssl=1)

*Default Mapping – Genabler applied for drain pipe sync*

1. Press Enter for the C3D and MES Network defined to have the parameters defined committed by the software.
2. It is recommended to tick ‘MiTS Platform Surface As Priority’ and select the ‘Default Surface Reference’ to **ensure the insertion point for the structures tallies with the Ground Level detected in MiTS**.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image17.png?w=1080&ssl=1)

1. Under the Project Dialog, go to the **Style Settings** tab. With Genabler, the long sections of the gravity networks in MiTS will be synced as the Profile View. Therefore, the band sets will be set to the dedicated Genabler Stylings (Hence, the options for the Band Set is disabled)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image1-2.png?w=1080&ssl=1)

*Profile View Styles of the Sewer Pipe Sync*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image5-2.png?w=1080&ssl=1)

*Profile View Styles of the Drain Pipe Sync*

1. If you **wish to only sync the gravity network (sewerage/drainage) in MiTS**, you may proceed to set the Sync. Mode for other entities to NoSync.
2. If you wish to sync other entities as well, you may proceed to follow the guides available on our website.
3. Click OK to close the Project Dialog. Then, click on **Load From MiTS** and click OK to sync the entity.

[https://www.youtube.com/embed/2VRR7IHWlL4?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/2VRR7IHWlL4?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

After sync, one can see that the manhole’s 3D shape is identical between MiTS and Civil 3D after sync:

![Civil 3D vs MiTS manhole shape](https://i0.wp.com/mes100.com/wp-content/uploads/2026/09/c3d-mits-manhole-shape-comparison-1.png?w=1080&ssl=1)

[https://www.youtube.com/embed/_e0a5G6FgYU?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/_e0a5G6FgYU?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

### *Related*

 [![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/10/me-small.jpg?resize=100%2C100&ssl=1)](https://mes100.com/author/admin/)[Ngu Soon Hui](https://mes100.com/author/admin/)

I’m the [Benevolent Dictator for Life](https://en.wikipedia.org/wiki/Benevolent_dictator_for_life) for MiTS Software cum Editor of this website. Read more [here](/about-ngu-soon-hui/).

You can also contact me at soonhui@mes100.com
