title: Gravity Networks Automation (Sewerage/Drainage)
description: "![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image63.png?resize=1024%2C511&ssl=1) *Sewerage Network Synced* ![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image64.png?resize=1024%2C519&ssl=1) *Drainage Network Synced* # **Profile View** The Profile View will be automatically generated for gravity networks (sewerage/drainage) synchronized from MiTS to Civil 3D. The generated diagram should correspond with the Long Sections in MiTS. ![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image4-4.png?resize=1024%2C887&ssl=1)…"
url: "https://mes100.com/docs/gravity-networks-automation-sewerage-drainage/"
updated: "2026-08-24"
category: "MCIntegrator-Genabler / Output"
tags:
  - BIM
---

# Gravity Networks Automation (Sewerage/Drainage)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image63.png?resize=1024%2C511&ssl=1)
*Sewerage Network Synced*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image64.png?resize=1024%2C519&ssl=1)
*Drainage Network Synced*

# **Profile View**

The Profile View will be automatically generated for gravity networks (sewerage/drainage) synchronized from MiTS to Civil 3D. The generated diagram should correspond with the Long Sections in MiTS.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image4-4.png?resize=1024%2C887&ssl=1)
*Profile View of Sewerage Network*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image46.png?resize=1024%2C869&ssl=1)
*Profile View of Drainage Network*

## **Steps:**

1. Each profile view has been set to the dedicated Genabler Stylings. To check or update the stylings, users may navigate to the **Profile View Properties**.

Select any of the Profile Views for the network > Right-click > Click on Profile View Properties

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image48.png?resize=1024%2C563&ssl=1)

1. The Profile View is also set to follow the dedicated **Genabler Bandsets Selection**. To check or update the bandsets selection,

Under the Gravity Networks Automation section, click on the ‘Profile View’ dropdown > Click on ‘Change Profile View Bandsets’

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image14-1.png?resize=1024%2C217&ssl=1)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image1-3.png?resize=1024%2C475&ssl=1)

1. To **clear the Profile View**,

Under the Gravity Networks Automation section, click on the ‘Profile View’ dropdown > Click on the ‘Clear Profile View’ button

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image45.png?resize=1024%2C217&ssl=1)

# **Gravity Table**

This is a feature that allows users to add a Sumps and Pipes/Drains Table following the dedicated Genabler Styling.

## **Steps:**

1. Go to the MES Tab. Navigate to the Gravity Networks Automation section on the top ribbon.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image31-1.png?resize=1024%2C115&ssl=1)

1. Click on the dropdown of the ‘Gravity Table’ button. Click on ‘Add Table’.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image59.png?resize=1024%2C203&ssl=1)

1. The software will launch the Pipe Table Creation. Set the **Table Style** (by default, it is set to the dedicated Genabler Styling), **Network**, and **Table Configurations** (rows, columns, table behavior, etc.).

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image32-1.png?resize=1024%2C499&ssl=1)

1. Click OK. Select the upper left corner to place the table on the drawing. Once the table has been set, the software will open up the **Structure Table Creation**, which requires users to set the stylings and table behaviors.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image42.png?resize=1024%2C537&ssl=1)

1. Click OK to place the **Structure Table**. Do note to place the **Sumps Table at a gap** from the **Pipes/Drains Table** to prevent overlapping between the two tables.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image34-1.png?resize=1024%2C440&ssl=1)

# **Networks Labeling**

Each of the structures (nodes) and pipes/drains is labeled with the properties, following the dedicated Genabler Stylings.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image56.png?resize=966%2C799&ssl=1)

## **Steps:**

1. To check or update the stylings, users may navigate to the **Structure Label Style** by,

Selecting any of the labels of the network > Right-click > Edit Label Style

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image55.png?resize=1024%2C750&ssl=1)

1. To update the properties displayed as the label,

Under the Gravity Networks Automation section, click on the ‘Label’ dropdown > Click on ‘Change Plan Label’

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image26-1.png?resize=1024%2C194&ssl=1)

1. To **clear the Labels**,

Under the Gravity Networks Automation section, click on the ‘Label’ dropdown > Click on the ‘Clear Plan Label’ button

![](https://i0.wp.com/mes100.com/wp-content/uploads/2026/08/image38-1.png?resize=1024%2C194&ssl=1)

### *Related*

 [![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/10/me-small.jpg?resize=100%2C100&ssl=1)](https://mes100.com/author/admin/)[Ngu Soon Hui](https://mes100.com/author/admin/)

I’m the [Benevolent Dictator for Life](https://en.wikipedia.org/wiki/Benevolent_dictator_for_life) for MiTS Software cum Editor of this website. Read more [here](/about-ngu-soon-hui/).