title: Creating Sewerage Network System
description: "With **Node** and **Sewer** button, a sewerage system can be easily be modeled in MiTS. ## **Node** ![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image2.png?w=1080&ssl=1) - Click on the “**Node**” button to input the manhole structure on the Input Screen - Click once anywhere on the Input…"
url: "https://mes100.com/docs/creating-sewerage-network-system/"
updated: "2026-08-24"
category: Sewer
---

# Creating Sewerage Network System

With **Node** and **Sewer** button, a sewerage system can be easily be modeled in MiTS.

## **Node**

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image2.png?w=1080&ssl=1)

- Click on the “**Node**” button to input the manhole structure on the Input Screen
- Click once anywhere on the Input Screen to activate your cursor into input mode
- Then, users can start to locate the nodes on the Input Screen

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image5-1.png?w=1080&ssl=1)

*Example of* how the Node will look *on the Input Screen*

**Note: Object Snapping**

It can be called out either by Ctrl + right-mouse click, or clicking the “*Snap*” button. Users should ensure the necessary Snap Modes have been activated for a precise input.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image1-2.png?w=1080&ssl=1)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image4.png?w=1080&ssl=1)

*The “Snap” button is located at the right-hand side Input Setting Grid*

## **Sewer**

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image3-4.png?w=1080&ssl=1)

1. Input the sewer on the Input Screen by clicking the “**Sewer**” button.
2. To input a sewer, users have to connect one node to another.

[https://www.youtube.com/embed/2k5I0cZScbQ?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/2k5I0cZScbQ?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

1. Users are also able to input the exact sewer pipe length by keying in the desired length.
   - Click once on the Input Screen to activate the cursor into input mode
   - Click the first node and key in the sewer length

[https://www.youtube.com/embed/rcP5JMaOnIk?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/rcP5JMaOnIk?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

### Import Sewer Pipe from ACAD

Click Import, select the ACAD file, and tick only the layer that contains the pipe network from the ACAD drawing.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2022/09/Import-Sewer-Pipe.png?w=1080&ssl=1)

![](https://i0.wp.com/mes100.com/wp-content/uploads/2022/09/Select-Layer.png?w=1080&ssl=1)

### **Import Drain with ‘z-values’**

Z-level refers to the invert level of the pipe. 

If the lines in the ACAD have internal Z values defined in the Properties, tick “Import Z Levels” checkbox to import the invert levels automatically.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2022/09/Import-Z-Levels.png?w=1080&ssl=1)

*Once layer and settings have been configured, click Import at the bottom right corner*

### **Features of Sewer**

Users can (1) break, (2) extend, (3) map node to sewer and (4) add parallel sewer line, by selecting the sewer, and then right-click on the selected sewer.

#### **Break Sewer**

Users can break sewer pipes from one to several pipes by having a node in between.

[https://www.youtube.com/embed/es8rPxCn9MM?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/es8rPxCn9MM?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

#### **Change Length**

Users have the flexibility to change the existing sewer pipe length by shortening or lengthening the sewer pipe.

[https://www.youtube.com/embed/g2l4KxSpfSc?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/g2l4KxSpfSc?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

#### **Map Node to Sewers**

Users can map a node to a created sewer network by clicking “**Map Node to Sewers**“.

[https://www.youtube.com/embed/jIfws9JDt_w?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/jIfws9JDt_w?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

#### **Create Offset Sewers**

Users can offset parallel sewer pipes by inserting distance intervals.

[https://www.youtube.com/embed/rtXdxmiL0EA?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/rtXdxmiL0EA?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)