description: "# **Vertical** ## **Key Plan** MiTS-Clash Analysis can generate a key plan based on the network systems. ![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image8.png?resize=1024%2C541&ssl=1) - **Insufficient Warning** - A yellow sign will be displayed indicating the vertical clearance between 2 pipes/drains is ***less than the Min.…"
url: "https://mes100.com/docs/clash-analysis-outcome/"
updated: "2024-08-07"
category: Integration
---

# Clash Analysis Outcome

# **Vertical**

## **Key Plan**

MiTS-Clash Analysis can generate a key plan based on the network systems.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image8.png?resize=1024%2C541&ssl=1)

- **Insufficient Warning**
  - A yellow sign will be displayed indicating the vertical clearance between 2 pipes/drains is ***less than the Min. Vertical Clearance set under the parameter*** (The default value is 300mm)

- **Clash Warning**
  - A red sign will be displayed indicating clearance between 2 pipes ***less than the material thickness***

Note:

**Clicking on the sign once will link to the conflict point in the report*

***Right - click on the sign to show the conflict point in 3D View or Long Section*

[https://www.youtube.com/embed/HtR8fwl-xg4?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/HtR8fwl-xg4?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

## **Report**

MiTS-Clash Analysis can generate a detailed report for every intersection point.

**Double-click on the rows will link back to the conflicting point in the Key Plan - Clash Analysis*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image5.png?resize=1024%2C542&ssl=1)

### **Remark**

| **Remark** | **Explanation** |
| --- | --- |
| **OK** | The entities are crossing on the horizontal plan in *correct* order (i.e. Water pipe is higher than the sewer pipe) and the vertical clearane is *more than the Min. Vertical Clearance* set. |
| **Clash** | **Negative clearance** for the entities crossing horizontally. Do note that for vertical clearance, any clash either with the outer or inner profile will result in a negative value. |
| **Insufficient** | The entities have **positive clearance** when crossing horizontally, but the distance between them is * less that the Min. Vertical Clearance* set. |
| **Inverse** with remarks such as *Drain is below sewer pipe* | Based on the assumption that (1) Drain is **above** the water pipe  (2) Water pipe is **above**the sewer pipe The remark will be shown once this order is not maintained, even if there is positive clearance with a distance more than the Min. Vertical Clearance set |

### **Vertical Clearance Computation**

***Note: The IL considered should be at the conflicting point on the pipes or drains*

| **Between** | **Vertical Clearance** |  |
| --- | --- | --- |
| Sewer | Drain | (Drain IL - Drain Thickness) - (Sewer + Sewer Pipe Diameter + Sewer Pipe Thickness) |
| Drain | Water | (Drain IL - Drain Thickness) - (Water IL + Inner Diameter + Water Pipe thickness) |
| Sewer | Water | (Water IL - Water Pipe thickness) - (Sewer IL + Sewer IL + Sewer Pipe thickness) |

# **Horizontal**

Horizontal clash analysis has been improved to give users a sense of a more realistic crash. Refer to this blogpost for more explanation and calculation details - [***Improved Horizontal Clash Analysis Benchmark***.](https://mes100.com/blog/improved-horizontal-clash-analysis-benchmark/)

## **Key Plan**

MiTS-Clash Analysis can generate a key plan based on the network systems. 

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image8-1.png?resize=1024%2C541&ssl=1)

- **Clash Warning**
  - A red sign will be displayed indicating a sump or manhole clashed with another entity

- **Yellow Warning**
  - A yellow sign will be displayed indicating horizontal clearance between the entities is ***less than the Min. Horizontal Clearance***. (The default value is 600mm)

Note:

**Clicking on the sign once will link to the conflict point in the report*

***Right-click on the sign to show the conflict point in 3D View or Long Section*

[https://www.youtube.com/embed/HtR8fwl-xg4?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/HtR8fwl-xg4?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

## **Report**

MiTS-Clash Analysis can generate a detailed report for every clashed point.

**Double-click on any rows will link back to the conflicting point on the key plan.*

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image27.png?resize=1024%2C579&ssl=1)

### **Remark**

The shortest perpendicular distance needed to avoid clashing between two entities, *can be between node-node or node-pipe*.

| **Remark** | **Explanation** |
| --- | --- |
| Clashing with "**-ve**" **clearance** | The clashing is happening inside at least one of the inner profiles of the two entities |
| The clashing is happening between the material thickness (It is happening outside of the inner profle of both entities but inside the outer profiles of the two entities) |  |
| Insufficient clearance ("**+ve**" **clearance**) | The entities **are not clashing**, but the horizontal distance between them is *less than the Min. Horizontal Clearance* set |

# **Long Section**

Users may view the long section by right-clicking on the warning and selecting the long section from the options available such as below.

[https://www.youtube.com/embed/woDI_-mUizQ?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1](https://www.youtube.com/embed/woDI_-mUizQ?version=3&rel=1&showsearch=0&showinfo=1&iv_load_policy=1&fs=1&hl=en-US&autohide=2&wmode=transparent&enablejsapi=1)

## **Drain Long Section**

MiTS - Clash Analysis can generate a drain long section with the water pipes and/or sewer pipes shown at the intersection point.

The long section will also display the Invert Levels (Material thickness has been taken into account) of the pipes/drains at the intersecting points.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image22.png?resize=1024%2C571&ssl=1)

## **Sewer Long Section**

MiTS - Clash Analysis can generate a sewerage long section with the water pipes and/or drains shown at the intersecting points.

The long section will also display the Invert Levels (Material thickness has been taken into the account) of the pipes/drains at the intersecting points.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image15.png?resize=1024%2C597&ssl=1)

## **Water Long Section**

MiTS - Clash Analysis can generate a water reticulation long secting with the drains and/or sewer pipes shown at the intersecting points.

The long section will display the Invert Levels (Material thickness has been taken into account) of the pipes/drains at the intersecting points.

![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/08/image17-1.png?resize=1024%2C671&ssl=1)

# Related Articles

- [**Starting Clash Analysis**](https://mes100.com/docs/starting-clash-analysis/)

- [**Clash Point Solution**](https://mes100.com/docs/clash-point-solution/)

### *Related*

 [![](https://i0.wp.com/mes100.com/wp-content/uploads/2024/10/me-small.jpg?resize=100%2C100&ssl=1)](https://mes100.com/author/admin/)[Ngu Soon Hui](https://mes100.com/author/admin/)

I’m the [Benevolent Dictator for Life](https://en.wikipedia.org/wiki/Benevolent_dictator_for_life) for MiTS Software cum Editor of this website. Read more [here](/about-ngu-soon-hui/).

You can also contact me at soonhui@mes100.com